CLT01-38S4点击型号即可查看芯片规格书
芯片规格书搜索工具-icspec
产品概述
描述
CLT01-38S4 adds to the existing current limiter family. Still focusing on power consumption savings, the whole series allows each customer to find the right solution.
The CLT01-38S4 is an octal input termination device with a high speed SPI output. Its maximum input data rate is 400 kbps while the output SPI speed is 6.25 MHz.
As in previous versions, robustness is a key feature of CLT01-38S4. The product is compliant with surge standards defined in IEC 61000-4-x.
It can run all types of sensor according to IEC 61131-2. Type 1 and 3 with a 2.35 mA limited current and type 2 using two inputs per sensor with the correct RREF.
所有功能
- 8-input circuit in common ground low side topology
- Wide range input DC voltage VI: -30 V to 35 V
- On state threshold: < 11 V with RI= 2.2 kΩ
- Off state threshold: Iin> 1.5 mA or Vi> 5 V
- Protected against -30 V reverse polarity
- Typical ILIM= 2.1 to 2.6 mA adjustable current limiters
- Tight current tolerance including temperature compensation: ±10%
- Serial output with an SPI communication bus
- Clock frequency up to 6.25 MHz
- CPHA = CPOL = 0 bus master operation
- Multi CLT operation in daisy chain connection
- 16-bit mode: 8 bits for data / 8 bits for control
- Minimum capture time: 4 μs
- Input data rate: 200 kbps/100 kHz
- Minimum propagation transfer time: 7 μs
- 8-bit mode: 8 bits for data
- Minimum capture time: 2.5 μs
- Input data rate: 400 kbps/200 kHz
- Minimum propagation transfer time: 4 μs
- VCC = -0.3 to +35 V with RC = 2.2 kΩ
- Ambient temperature range: -25 to +85°C
- Digital inputs for programmable logic controller and decentralized I/O modules
- Benefits
- Enables input to meet type 1, 2 and 3 characteristics of IEC 61131-2 standard
- Compatible operation with 2 wires proximity sensor according EN 60947-5-2 standard
- Compact board with surface mount integration and reduced count of isolated couplers
- Reduces the count of input-output of the bus controller circuit
- Provides energy-less input LED visual status
- Enhanced functional reliability
- Built-in over voltage robustness and immune data transfer
- Reduced dissipation: 78 mW max. per channel
- Complies with following standards (RI= 2.2 Ω, RC= 2.2 Ω, C = 33 nF):
- Electrostatic discharge, IEC 61000-4-2:
- ±8 kV contact discharge
- ±15 kV air discharge
- Electrical transient immunity IEC 61000-4-41:
- FSCK= 6.25 MHz, ±3 kV
- FSCK= 10 kHz, ±4 kV
- Voltage surge IEC 61000-4-5
- Input: ±15 kV
- Power supply: ±2.5 kV